Types of Grit Chambers in Waste Water Treatment
Check the SLR (1200-1700 m3/m2-day) and Vs (≥ 0.01 m/sec). Grit produced is about 1.5 ft3/ML of wastewater flow. Add to depth {1ft FB + grit}... Assume a depth (D = 08-15 ft), determine the surface area of the basin. And check the SLR (1200-1700 m3/m2-day)... The amount of grit produced is about 1.5 ft3/ML of wastewater flow. Add suitable depth from